After E. L. Wilson, A. Der Kiureghian, E. P. Bayo,“A replacement for the srss method in seismic analysis”, Earthquake Engineering & Structural Dynamics (1981), doi:10.1002/eqe.4290090207.
- Against the closed form
- 9 of 9 checks pass· see the checks
- Against the paper’s figures
- The paper’s building and tables are not used: this page checks its own two-mode example against the closed form.
Research, not a design tool. Nothing here is an engineering result.
One small 3D shear-building idealization, solved by the production modal and response-spectrum engine.
The example
Four fixed-base columns, 3 m high on a 4 × 3 m plan. Each roof node carries 5 t in X. Roof rotations and Y/Z translations are restrained; equal-X constraints join each transverse pair. Two axial roof ties couple the two remaining coordinates. This is our illustration of the method, not the paper’s original building.
Closed-form reference
The reduced matrices are M = diag(10, 10) t and K = [[1020, −20], [−20, 1230]] kN/m. Solve det(K − ω²M) = 0; normalize each mode to unit modal mass. For Sa = 1 m/s², the modal base shears are Γ²Sa. SRSS discards cross terms; CQC retains their equal-damping correlation at ξ = 5%.
ρ(r, ξ) = 8ξ²(1+r)r³ᐟ² / [(1−r²)² + 4ξ²r(1+r)²], r = ω₂/ω₁.
This is the equal-damping correlation coefficient of Wilson, Der Kiureghian and Bayo (1981), Eq. (14), p. 191; p. 190 explains why the cross terms keep their sign. It assumes equal modal damping, ground motion that lasts long compared with the modal periods, and a broad, smooth spectrum. The reference values below are closed-form results for this example, not data from the paper’s Table I.
The paper proposes CQC to reduce modal-combination errors and recovers SRSS for well-separated frequencies. Here SRSS is lower than CQC for base shear. This difference is relative to the CQC estimate, not a measured error against an earthquake record.
Checks
Regression bound: relative difference below 1 × 10⁻⁸ for both frequencies, the X mass participation, both base shears and both roof displacements (9 checks). The native run differs by at most 6.4 × 10⁻¹⁵. The bound guards this small, well-conditioned two-coordinate problem against regressions; it is not an accuracy target, and agreement between solver and closed form says nothing about physical accuracy.
Scope
- The comparison is with the closed form of this two-coordinate example; the paper’s own building and numerical tables are not reproduced.
- No time history: neither rule is measured against a ground-motion record.
- One storey, no torsional response and no parameter sweeps.
Cite this
Stabileo Research, “Closely spaced modes: SRSS vs CQC”, method illustration based on E. L. Wilson, A. Der Kiureghian, E. P. Bayo (1981), doi:10.1002/eqe.4290090207. Implementation: research/benchmarks/cqc-1981 at commit fb241aa04936. Engine: the Stabileo engine at the same commit.