After E. Riks,“An incremental approach to the solution of snapping and buckling problems”, International Journal of Solids and Structures (1979), doi:10.1016/0020-7683(79)90081-7.
- Against closed form and native engine
- 3 of 3 checks pass· see the checks
- Against the paper’s figures
- This is a method benchmark against analytical equilibrium and native production results. It does not reproduce a numerical example from Riks (1979) or Crisfield (1981).
Research, not a design tool. Nothing here is an engineering result.
Stabileo’s production arc-length solver follows two two-bar frames, and every recorded point is compared with an analytical equilibrium path.
Method
Load control stops at a horizontal tangent (dP/dv = 0) on this load–displacement chart. Crisfield’s spherical arc-length constraint couples displacement and load increments: ‖Δu‖² + Δλ²‖f_ref‖² = Δs².
The method papers are E. Riks, “An incremental approach to the solution of snapping and buckling problems” (1979), and M. A. Crisfield, “A fast incremental/iterative solution procedure that handles ‘snap-through’” (1981).
Models and references
Both models are frames with pinned bases and a rigid apex. The historical shallow frame uses its bending-inclusive energy derivative. The slender von Mises frame is compared with axial truss equilibrium; its replay passes the upper limit only, not the full snap-through or lower limit.
L₀ = √(a² + h²); y = h − v; L = √(a² + y²); β = atan(y/a) − atan(h/a). P = 2EA(1 − L/L₀)y/L; U = EA(L−L₀)²/L₀ + 3EIβ²/L₀; P_frame = P − 6EI a β/(L₀L²).
Comparison on this run
Stabileo passes the upper limit point: 3/3 checks pass
| Check | Error | Tolerance | Result |
|---|---|---|---|
| Upper limit load (kN) | 2 × 10−5 | 1 × 10−3 | pass |
| Displacement at upper limit (m) | 1 × 10−4 | 5 × 10−3 | pass |
| Maximum normalized path residual | 2.3 × 10−5 | 5 × 10−5 | pass |
A converged load reversal brackets the upper limit; a parabola through three adjacent points estimates its position. Each metric has its own tolerance in the case file. An unreached limit is not evaluated. The load-factor increment Δλ is bounded by Δs / ‖f_ref‖; this is a sampling bound, not an accuracy claim.
Comparison scope
This is a method benchmark against analytical equilibrium and native production results. It does not reproduce a numerical example from Riks (1979) or Crisfield (1981).
Every displacement frame is an independent production solve with the full step prefix checked. The native/WASM comparison checks iterations, convergence and displacements. These symmetric 2D cases do not validate bifurcation or 3D behavior. Research, not a design tool.
Cite this
Stabileo Research, “Arc-length benchmarks: Riks and Crisfield”, benchmark of the method of E. Riks (1979), doi:10.1016/0020-7683(79)90081-7. Implementation: research/numerical-methods/riks-crisfield at commit fb241aa04936. Engine: the Stabileo engine at the same commit.