Research / Numerical methods

Arc-length benchmarks: Riks and Crisfield

After E. Riks,“An incremental approach to the solution of snapping and buckling problems”, International Journal of Solids and Structures (1979), doi:10.1016/0020-7683(79)90081-7.

Against closed form and native engine
3 of 3 checks pass· see the checks
Against the paper’s figures
This is a method benchmark against analytical equilibrium and native production results. It does not reproduce a numerical example from Riks (1979) or Crisfield (1981).

Research, not a design tool. Nothing here is an engineering result.

Stabileo’s production arc-length solver follows two two-bar frames, and every recorded point is compared with an analytical equilibrium path.

Method

Load control stops at a horizontal tangent (dP/dv = 0) on this load–displacement chart. Crisfield’s spherical arc-length constraint couples displacement and load increments: ‖Δu‖² + Δλ²‖f_ref‖² = Δs².

The method papers are E. Riks, “An incremental approach to the solution of snapping and buckling problems” (1979), and M. A. Crisfield, “A fast incremental/iterative solution procedure that handles ‘snap-through’” (1981).

Models and references

Both models are frames with pinned bases and a rigid apex. The historical shallow frame uses its bending-inclusive energy derivative. The slender von Mises frame is compared with axial truss equilibrium; its replay passes the upper limit only, not the full snap-through or lower limit.

L₀ = √(a² + h²); y = h − v; L = √(a² + y²); β = atan(y/a) − atan(h/a). P = 2EA(1 − L/L₀)y/L; U = EA(L−L₀)²/L₀ + 3EIβ²/L₀; P_frame = P − 6EI a β/(L₀L²).

Comparison on this run

Stabileo passes the upper limit point: 3/3 checks pass

CheckErrorToleranceResult
Upper limit load (kN)2 × 10−51 × 10−3pass
Displacement at upper limit (m)1 × 10−45 × 10−3pass
Maximum normalized path residual2.3 × 10−55 × 10−5pass

A converged load reversal brackets the upper limit; a parabola through three adjacent points estimates its position. Each metric has its own tolerance in the case file. An unreached limit is not evaluated. The load-factor increment Δλ is bounded by Δs / ‖f_ref‖; this is a sampling bound, not an accuracy claim.

Comparison scope

This is a method benchmark against analytical equilibrium and native production results. It does not reproduce a numerical example from Riks (1979) or Crisfield (1981).

Every displacement frame is an independent production solve with the full step prefix checked. The native/WASM comparison checks iterations, convergence and displacements. These symmetric 2D cases do not validate bifurcation or 3D behavior. Research, not a design tool.

Cite this

Stabileo Research, “Arc-length benchmarks: Riks and Crisfield”, benchmark of the method of E. Riks (1979), doi:10.1016/0020-7683(79)90081-7. Implementation: research/numerical-methods/riks-crisfield at commit fb241aa04936. Engine: the Stabileo engine at the same commit.