Re-run affected concrete and steel design checks. For generated snow, regenerate the loads first, then re-run affected load cases, combinations, envelopes and derived design checks. Re-solving previously saved loads alone does not repair them. Compare demands, capacities, reinforcement, utilization, governing combinations and certificates with results already used. Review delivered calculations and sizing based on them. A refusal, an unavailable quantity or unchecked reinforcement supplies no passing answer and is not zero demand.
Safety advisories
| Advisory | Severity | What changed and what to do |
|---|---|---|
| SA-2026-064 | High | Steel Cb could come from another combination or an unlocated short unbraced span (#1316, #2088). Re-run CIRSOC 301 steel checks and review flexural capacity, interaction utilization and governing combinations. |
| SA-2026-065 | High | Roof-step drift could be omitted on a pitched receiving roof (#2082). Regenerate CIRSOC 104 snow loads and re-run affected analyses and design checks. |
| SA-2026-066 | High | Concrete Cm could receive end-moment credit with transverse load between supports (#2089). Re-check slender concrete columns and walls, magnified moments and reinforcement. |
| SA-2026-067 | High | Plan rotation could change generated snow loads (#2093). Regenerate loads using the actual roof geometry, then re-run analyses and checks; rotating an old model back is not a repair. |
| SA-2026-068 | High | Torsion could pass with inadequate designed stirrups (#2141). Re-run concrete design checks and review actual transverse capacity, stirrup spacing and torsion failures. Unchecked longitudinal provision is not a passing cage. |
Every results-change notice since v0.6.0
The registry at v0.6.0 ends at results version 78; this release reaches 80. The table lists all 24 new notices. Several notices share a version. Re-run every applicable check; for snow notices, regenerate loads before re-solving.
| Results version | Result that changes |
|---|---|
| 79 | Snow drift coverage follows continuous roof edges |
| 79 | Snow overrides preserve unbalanced sides and section runs |
| 79 | Flat snow frames follow connected roof runs |
| 79 | Snow loads respect local positions and drift boundaries |
| 79 | Snow factors follow each roof orientation |
| 79 | Snow cases cover every ridge orientation |
| 79 | Snow fetch follows continuous roofs and selected geometry |
| 79 | Snow loads retain their magnitude under plan rotation |
| 79 | Roof-step drift uses the receiving roof plane |
| 79 | Snow loads follow each connected roof surface |
| 79 | Snow tributaries use interior roof surfaces |
| 80 | Member checks require every active combination |
| 80 | Complete station data is required for member checks |
| 80 | Concurrent checks retain governing demands |
| 80 | Design uses selected bars and known span loading |
| 80 | Interaction checks use concurrent station forces |
| 80 | Concrete checks retain secondary slenderness |
| 80 | Concurrent cases retain all required torsion reinforcement |
| 80 | Fixed reinforcement retains the practical maximum check |
| 80 | Design demands respect behaviour and flange spans |
| 80 | Torsion checks every returned stirrup cage |
| 80 | Shared beams retain their axes; torsion provision must be stated |
| 80 | Steel interaction Cb uses its own combination diagram |
| 80 | Steel stations use physical lengths and retain shear demands |

Other changes
Concrete and steel checks retain forces from the same combination and station. Incomplete combination or station data now refuses instead of borrowing an endpoint result. Required and provided reinforcement states remain separate, and missing longitudinal torsion provision is reported explicitly.
Known limitations
- Known wrong results remain open: #2096, #2142, #2143 and #2144. This release does not fix them. Consult their affected scope and independently verify affected results before use.
- SA-2026-056 remains unfixed: independently verify dynamic demands for constrained mixed frame-and-shell models that change materially after renumbering, rotation or unit conversion. No conservative correction factor is established.
- 2D plastic collapse remains refused pending #758, as described in SA-2026-044. A certified 3D lower bound does not certify the raw hinge history.
- Time history does not provide total dynamic support demands. Use an independent analysis including inertia, damping and support loading. Unsupported cable analyses and nonzero prescribed support motion in cable/time-history workflows refuse explicitly.
- Spatial arc-length and displacement-control solvers are not added. Existing warnings and restrictions remain applicable.