Results
Certified (linear solve)· relative error bound ≤ 2.8 × 10−6
Top drift against outrigger height (mm)
A square concrete box core (E = 30 GPa, walls 0.3 m) is a cantilever under a uniform wind load. One stiff outrigger (I = 2 m⁴) ties it to two perimeter columns, pinned at the ground and at the outrigger, which carry only axial force. Each slider move solves the model once for the chosen level and once for every storey, so the chart is the engine’s own sweep. The top drift and the column force are shown beside the Smith & Coull compatibility solution for one outrigger, with the outrigger’s bending and the columns’ shortening included.
Verified by: Tools: cantilever beam, checked against closed forms
A teaching example, not a design check. SI units: m, kN, MPa. Published by Ergodic Group.